| Equipment Type |
Model Number |
Description / Function |
Suitable For |
Image |
| API Coupler |
3659 |
4" API Coupler |
Bottom Loading |
View |
|
| Vapour Coupler |
3682 |
4" Vapour Coupler |
Bottom Loading |
View |
|
| Vacuum Breaker |
2336 |
For 3" & 4" Loading Arms. 3/8" API male threaded. For quick drainage after closing the Loading Valve |
Top Loading Arms |
View |
|
| Vacuum Breaker |
2361 |
For 6" Loading Arms. 3/4" or 1" API male threaded. For quick drainage after closing the Loading Valve |
Top Loading Arms |
View |
|
| Loading Valve |
504 |
Available in 3", 4" & 6". Choice of Stay or Hold Open. Seal Materials- Nitrile or Viton. With dual poppet for ease of opening and shockless closure. |
Top Loading Arms |
View PDF
|
|
| Loading Valve Limit Switch |
2305 |
The switch is operated by movement of the valve lever and gives a closed contact when the valve is flow condition. |
Top Loading Arms |
View |
|
| Sight Glass Indicator |
2424 |
Visual indication of product contained in the Arm. |
Top/Bottom Loading Arms / Stand / Riser Posts |
View |
|
| Overfill Alarm Pneumatic |
2794 |
For the prevention of overfill. The pneumatic circuit continually bleeds a small flow of air out through the sensing tube. When the sensing
tube is submerged in the liquid the amplified back-pressure signal closes (or opens) an EEx-d electrical contact. The air logic re-sets when the sensor
/ drop tube is withdrawn. For connection to Alarm.
|
Top Loading Arms Fixed Reach Long Reach |
View |
|
| Overfill Shut-Off Pneumatic |
3013 |
For the prevention of overfill. The pneumatic circuit continually bleeds a small flow of air out through the sensing tube. When the sensing tube is
submerged in the liquid the amplified back-pressure signal closes the loading valve (or ball valve). The air logic re-sets when the sensor / drop
tube is withdrawn from the liquid. In addition the loading valve will automatically close in the event of an air failure. Operation by push button control.
|
Top Loading Arms Fixed Reach Long Reach |
View |
|
| Overfill Device Electrical |
|
For the prevention of overfill. The product sensor is designed to signal on contact with liquid level giving either a signal to an alarm,
ball / loading valve or pump. Information on request
|
Top Loading Arms Fixed Reach Long Reach |
|
|
| Luffing Switch |
2353 |
Permits loading only when arm is in the correct downward position. Shut-off is activated at 10° above horizontal. |
All Arm types |
View |
|
| Rotational Switch |
2354 |
Indicates side of gantry in use. Also fitted with stops to restrict angle of rotation and to prevent twisting and damage to cables. |
All Arm types |
View |
|
| Arm Locking Device |
2429 |
Hold arm in a pre-determined loading position |
Top Loading Fixed Long Reach |
View |
|
| Rotational Stop |
|
Prevents rotation over 360º Information on request |
All Arm types |
|
|
| Drip Bucket Clamp-on type |
2408- 3" 2408- 4" |
For 3" & 4" Loading Arms for connection to Drop Pipe |
Top Loading Arms |
View |
|
| Drip Bucket Hook-on type |
2410 |
For 6" Loading Arms for connection to Drop Pipe Information on request |
Top Loading Arms |
|
|
| Drop Pipe Fittings |
|
Coupling & Adapter - allows connection for meter proving. Supplied with either threaded or weld end connection. Aluminium with brass cams.
Available in various sizes and materials.
|
Top Loading Arms |
View Coupler
View Adapter
|
|
| End fittings |
|
Couplers / Adapters / Cam Arm / Threaded / Flanged. See products - Couplers / Adapters Others types available on request. |
Bottom Loading |
|
|
| Heat Tracing Insulation & Cladding |
|
There are three methods available for the heating of Loading Arm or Swivel Joint assemblies. By Oil, Steam or electrical tracing. Information on request |
Top / Bottom Loading Arms / Swivel assemblies |
|
|
| Break-Away Valves |
|
The Break-away is designed to safely disconnect without causing a product spillage. Information on request |
Bottom Loading |
|
|
| Hoses for Bottom Loading |
|
Available in Polypropylene, Stainless Steel or Rubber. Information on request |
Bottom Loading |
|
|
| Hose Identification Jackets |
|
Institute of Petroleum std colours. Polyurethane Padded jacket with Zip Fastener. Also protects tanker paint work. Available in various lengths and colours |
Bottom Loading |
|
|
| Paint Finish |
|
Institute of Petroleum std colours to identify loading arm product. Information on request |
All Arm types |
|
|
| Stand / Riser Posts |
|
6" x 4" post with Base Plate with vertical post. Inlet and Outlet connection flanges. Designed to site requirements. Available in various configurations |
Top / Bottom Arms |
|
|
| Butterfly Valve 4" |
|
Allows API Coupler to be removed with out having to drain the Loading Arm. |
Bottom Loading |
View Adapter |
|
| Static / Earth Discharge Reels |
|
Spring retractable cable return with Clamp. Wall mountable. Various types available |
Gantry |
|
|
| Hose Reel |
|
Spring retractable hose return. Housing with powder coated finish. Fitted with hose roller guides. Fuel oil resistant hose size 1", 1-1/2".
Wall mountable. Outlet Nozzles available on request. Various types available
|
Gantry |
|